Home / News / Article
Technical Guides

Ringlock Scaffolding Component List: Full BOM for a 1,000 m² Facade

2026-10-12 · By PJSCAFFOLD Engineering Team

Here is the complete bill of materials for 1,000 m² of fully boarded ringlock facade — a 50 m long × 20 m high elevation in the export-standard grid (1.8 m bays, 2.0 m lifts, double row, Q355B hot-dip galvanized):

≈ 20 tonnes total: 580 × 2.0 m standards · 560 × 1.8 m facade ledgers · 280 × 1.2 m transverse ledgers · 280 diagonal braces · 560 × 1.8 m steel planks · 58 adjustable base jacks.

That is the list to hand to a supplier for a project-scale enquiry. This article gives you each line with its counting rule and unit weight, the accessories that are almost always left off a parts list, and how to tell a serious BOM from a padded one.

Ringlock scaffolding components laid out for a bill of materials: standards, ledgers, braces, planks and base jacks

The Reference Structure

A bill of materials is meaningless without its assumptions. These are the fixed parameters for everything that follows — change any one of them and the quantities change with it.

ParameterValueWhy it matters
Facade size50 m long × 20 m high = 1,000 m²The scaling unit
SystemRinglock, 48.3 × 3.2 mm Q355BUnit weights below are for this tube
Bay grid1.8 × 1.2 mDefines bay count and ledger lengths
Lift height2.0 mDefines the number of levels
RowsDouble (inner + outer)Doubles standards and facade ledgers
BoardingEvery lift2 planks per bay per lift

If your project is a different size, the take-off formula reproduces every rule used here, and the conversion table scales the tonnage directly.

The Full Bill of Materials

ComponentSpecQtyUnit weightSubtotal
Standards2.0 m, 4 rosettes5809.7 kg5,626 kg
Facade ledgers1.8 m5607.3 kg4,088 kg
Transverse ledgers1.2 m2805.1 kg1,428 kg
Diagonal braces1.8 × 2.0 m bay2808.5 kg2,380 kg
Steel planks1.8 m, 0.61 m module56011 kg6,160 kg
Adjustable base jacks0–600 mm travel585.6 kg325 kg
Structural total≈ 20,007 kg ≈ 20.0 t

Each of those lines is a distinct order item with its own code — RS-200 for the 2.0 m standard, RL-180 for the 1.8 m ledger and so on. The full code list, lengths and weights are in the ringlock dimensions and size chart.

How Each Line Is Calculated

So you can reproduce the numbers — or audit someone else's:

ComponentRuleApplied here
Standards(bays + 1) × lifts × rows29 × 10 × 2 = 580
Facade ledgersbays × lifts × rows28 × 10 × 2 = 560
Transverse ledgersbays × lifts28 × 10 = 280
Diagonal braces≈ 2 per bay per lift at every second bay14 × 10 × 2 = 280
Steel planks2 per bay per boarded lift28 × 2 × 10 = 560
Base jacks(bays + 1) × rows29 × 2 = 58

Note the "bays + 1". A 28-bay facade needs 29 lines of standards, because the closing column at each end is a full column of steel. It is the line most often missing from a hand-prepared BOM, and it is roughly 3.5% of the standards on this project.

Accessories a BOM Must Not Forget

These items rarely appear on a drawing-based parts list and always appear on a site. They add roughly 2–4% to the total weight and are packed separately (cartons and pallets) rather than bundled with the tubes.

ItemAllowanceNote
Wedge pins≈ 1,200 pcsOne per ledger or brace connection; the highest-loss item on any site
Ties and anchor boltsBy designSet by the wind calculation, not by the bay count
Toe boardsPer boarded liftSafety requirement in most jurisdictions
GuardrailsPer lift, both rowsOften the same tube as the ledger, but must be counted
Access ladders / stair units1 per 2–3 liftsLadder or stair tower depending on height
Base plates and sole boards1 per standardThe jack stands on it; the ground carries the load
Spare planks1 boarded liftPlanks take the wear; a spare level keeps the site working
If a quotation reaches you without a wedge pin line, the pins are either included in the tube price — or the site will be buying them locally at retail. Ask which.

How to Read a Supplier's BOM

SignalWhat it usually means
Quantities only, no unit weightsYou cannot verify the tonnage — or the container count
Standards counted as bays, not bays + 1The BOM was produced from a drawing, not from a take-off
No wedge pin or tie lineAccessories will be priced separately, after you commit
"2.0 m standard, 7.2 kg"Thin-wall tube. Our 3.2 mm Q355B standard is 9.7 kg — a 7 kg offer is a different product
Planks quoted without module widthRinglock bays take 0.61 m and 1.07 m plank modules; a mismatch is discovered on site
No loading plan offeredThe supplier has not modelled how the mix fits a container. See our container loading guide

The single most useful check is the unit weight line. Everything else — tonnage, container count, freight, landed cost — is derived from it, so a weight that does not match the tube specification you asked for invalidates the whole document. Our ringlock scaffolding system page lists the certified unit weights per component.

Scaling the BOM Up and Down

  • Halve it. 500 m² maps almost linearly: about 290 standards, 10 tonnes, one part-loaded container. Linear scaling holds while the grid stays the same.
  • Change the grid. Move from 1.8 m to 2.4 m bays on the same 1,000 m² and standards drop from 580 to roughly 440 — a 24% saving on the heaviest line. Ledger sections and permissible loads must then be re-checked against the load chart.
  • Board fewer lifts. Planks are 31% of this BOM. Boarding the working lifts only instead of all ten cuts about 3 tonnes — and changes the dead load your engineer designs against.

Turning the BOM into an Order

A BOM this size lands almost exactly on one 40ft container, which is not a coincidence — 20 tonnes is the practical payload limit, and the grid is the one the market quotes against. Send us your own dimensions and we return the equivalent list for your project, with the loading plan and an indicative quotation attached. Send your facade dimensions →

Frequently Asked Questions

What components make up a ringlock scaffolding system?

Standards (verticals with welded rosettes), ledgers (horizontals), diagonal braces, forged wedge heads and wedge pins, base jacks and U-head jacks, steel planks, and access items such as ladders, guardrails and toe boards.

How many standards and ledgers are in 1,000 m² of ringlock?

For a 50 m × 20 m facade on the 1.8 × 1.2 m / 2.0 m grid, double row: about 580 × 2.0 m standards, 560 × 1.8 m facade ledgers, 280 × 1.2 m transverse ledgers and 280 diagonal braces.

How much does 1,000 m² of ringlock scaffolding weigh?

Approximately 20 tonnes fully boarded. Steel planks account for roughly 6 tonnes of that, which is why the boarding decision moves the tonnage more than any other single choice.

What is usually missing from a scaffolding parts list?

Wedge pins (allow one per connection, roughly 1,200 pieces), ties and anchor bolts, toe boards and guardrails, access ladders, and the sole boards or base plates the jacks stand on.

Can I order a mixed container rather than a pure component list?

Yes. Weight, not volume, is the binding constraint in a container, so mixed loads are standard practice. We prepare the loading plan so the mix reaches the payload target without exceeding axle or road limits.

Explore Our Scaffolding Systems

Ringlock Scaffolding

View details →

Cuplock Scaffolding

View details →

Frame Scaffolding (H-Frame)

View details →

Hot-Dip Galvanized Steel Planks

View details →

Connectors & Accessories

View details →

Get a Free Quote →

Keep Reading

← Back to News